Ad-weighing FX-300i-PT Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
20
Cleaning the thermometer
For accurate temperature measurement, keep the temperature detection part clean.
Wash the thermometer softly in water. If contamination is hard to remove, clean the thermometer
with a lint free cloth moistened with water and a mild detergent.
Specifications
Sensor : Thermister
Measuring temperature range : -50°C to 260°C
Display resolution : 0.1°C
Accuracy : ±1.0°C (0°C to 60°C), ±2.0°C (-20°C to 100°C),
±2.5°C (-50°C to 100°C), ±3.0°C (-50°C to 150°C),
±3.5°C (-50°C to 200°C), ±4.0°C (other)
Sampling interval : Regular every 10 seconds
FAST every 2 seconds
Water protection : JIS IPX7 (Endures a 30-minute immersion in a water depth of 1
meter at room temperature)
Power source : LR44 battery 1 piece
Battery life : Approx. 1 year
Operating environment : 0°C to 40°C, 75% RH or less, non-condensing
(Excluding the sensor sheath)
Storage environment : 0°C to 50°C, 75% RH or less, non-condensing
Sensor sheath dimensions : φ2.80, approx. 110 mm
Dimensions/mass : 176 x 40 x 16 mm, approx. 25 g (including the battery and sheath
protector)
Standard accessory : Sheath protector, battery